LORENTZ Solar Pumps in Perth/Australia
Perth 1
installed June 2005 by SOLCO/Perth
1.2 kWp system pump water from an old windmill well to a 100 m3 tank via a 2.0 km pipline and a total dynamic head of approx. 80 m lift. From this large tank a second pump is installed in a communicating cylinder (of the same water level as tank) that pushes water through a diameter 73 mm/3", 3.0 km pipline uphill
total dynamic lift 80 m
system: PS1200 HR10 with 1.2 kWp on single axis tracking mount
summer daily pumped water volume approx. 20 m3
Click on pictures to enlarge
Perth 2
720 Wp Array, ETAPUMP HR14, max. vertical lift 42 m
Pumping into two tanks:
Click on pictures to enlarge
Pictures Courtesy by B/W Solar, Australia
 |