system 1
pump system: PS2-1800 HR-14H
flow rate: 20 m³/day
total dynamic head (TDH): 70 m
solar generator: 1.3 kWp
system 2
pump system: PS2-1800 C-SJ8-7
flow rate: 40 m³/day
total dynamic head (TDH): 9 m
solar generator: 2 kWp
system 3
pump system: PSk2-7 HR-07
flow rate: 125 m³/day
total dynamic head (TDH): 60 m
solar generator: 10.6 kWp
system 4
pump system: PS2-600 HR-07
flow rate: 10 m³/day
total dynamic head (TDH): 40 m
solar generator: 780 Wp
Mkuranga
Tanzania
GadgetroniX.Net
August 2018
The client was using a conventional 1hp AC pump powered by a diesel generator to cultivate his farm. He wanted to convert the pump to use solar power, however it would still not give him the amount of water required for his daily use.
We offered a solution of PS2-1800 HR-14H-2 with with 1.28Kw of solar power at a head of about 70m and getting a daily average of 20,000L.
He He has now shifted to LORENTZ solar pump which is giving him more than double the amount of water he used to get per day without use of diesel and avoiding costs for servicing the generator.