system 1
pump system: PS2-1800 HR-23
flow rate: 30 m³/day
total dynamic head (TDH): 45 m
solar generator: 2.6 kWp
system 2
pump system: PS2-4000 CS-F16-3
flow rate: 150 m³/day
total dynamic head (TDH): 6 m
solar generator: 4.3 kWp
system 3
pump system: PS2-150 C-SJ5-8
flow rate: 5 m³/day
total dynamic head (TDH): 10 m
solar generator: 270 Wp
system 4
pump system: PS2-600 HR-07
flow rate: 10 m³/day
total dynamic head (TDH): 40 m
solar generator: 780 Wp
Tanzania
GadgetroniX.Net
December 2018
A new campsite is being built. This water will be initially used to put up the whole camp then once the camp is up and running, it will be used for drinking water, for the swimming pool and for the camp mess.