pump system: PS2-1800 C-SJ1-25
flow rate: 23 m³/day
total dynamic head (TDH): 90 m
solar generator: 4.1 kWp
Caserío Micoacan
Guatemala
Guatemala Solar
November 2026
Drinking water application, spring capture 70m below controller location, distance to pump 264m, motor cable #2 aluminium cable in conduit, well probe cable coax with a resistance of 54 ohm.
Turn off controll with pressure sensor, when each of the tanks of 1100liters is full and float valve shut off water, pressure rise triggers shut off pump. Hydrostatic tank in form of 2.9m 4" pipe installed in control room. Pressur rise is slow, no water hammer occurs, over pressure turn off 2 bar above sensor, enough to provide water to higher ground.
Solar generator oversizing because of foggy and cloudy conditions